Home/Blog/ Torque Wrench Calibration: A Buyer’s Checklist

Torque Wrench Calibration: A Buyer’s Checklist

Get OEM Tool Catalog + Quote Back to Tool Sourcing Blog
Adjustable torque wrench with a graduated setting scale
This KOLARWIN Tools article is written for overseas distributors, wholesalers, importers and private label tool brands sourcing mechanic tools, automotive repair tools, socket tools, hand tools and OEM tool sets from China. Use this guide to compare product options, check supplier quality points and move from reading to a faster B2B inquiry.

Need OEM supplier support for this product type?

Contact KOLARWIN Tools for OEM mechanic tools, private label packaging, wholesale quotation and product range support. This gives overseas buyers a clear path from article reading to supplier discussion.

For a distributor or quality buyer, a torque wrench certificate can look complete while leaving key questions unanswered: which range was tested, in which direction, and with what uncertainty? This checklist shows how to specify calibration evidence, compare supplier documents, and set incoming acceptance rules. ISO 6789-2 covers calibration and measurement uncertainty for hand torque tools; buyers can use its scope as a starting point, then match requirements to their process and market.

1. What should a buyer mean by torque wrench calibration?

Calibration compares a tool’s output with a reference under stated conditions. It records the relationship between indicated and measured torque, but does not adjust the wrench or predict future accuracy. ISO 6789-2:2017 covers calibration and measurement uncertainty; Part 1 addresses design and quality conformance. Check your market’s required edition. ISO’s standard page describes Part 2’s scope.

Separate these actions in purchase orders and quality records:

  • Calibration: records measured results against a reference and reports uncertainty.
  • Verification or checking: compares tool performance with a defined internal acceptance rule, often between formal calibrations.
  • Adjustment or repair: changes the tool or restores it after an out-of-tolerance result; it should lead to a new measurement record.

Here is the purchasing distinction: a calibration certificate reports evidence; your quality plan decides whether that evidence is acceptable for a specific process. A certificate can still fail your requirement if range, direction, or uncertainty misses the job. For product-type and mechanism context, see the existing professional torque wrench guide. Ask suppliers to name each service step rather than using “calibrated” as a catch-all.

Buyer record distinction

Record or service What it tells you What it does not prove by itself
Calibration result Relationship to a reference under stated conditions Future performance or automatic acceptance
Verification check Whether a defined check met your rule Full calibration across the required range
Adjustment or repair Work performed on the tool Acceptable performance until a post-work result is recorded

2. What makes a calibration certificate useful?

A useful report identifies the tool and work performed. Ask for manufacturer, model, serial or unique ID, date, procedure, range, units, direction, results, reference equipment, and uncertainty. Request as-found results before adjustment and as-left results afterward when your quality system requires them. Norbar describes this distinction in its calibration service documentation, where its certificates can show both sets of readings.

Check the report against the purchase specification before accepting a batch. A certificate stating only “pass” or “within tolerance” may hide the values needed for your own decision. A certificate without serial identification can also be difficult to connect to a particular wrench after goods enter stock.

  • Confirm tool identity matches the physical marking and packing list.
  • Confirm units and direction match the intended use.
  • Compare tested points with the specified operating range.
  • Confirm uncertainty and the calibration reference are reported or traceable in the agreed way.

A clean document trail saves a second inspection. Link each certificate to the tool ID, lot, receiving record, and service history. Assess factory certificates against your written requirement. Put required fields in the RFQ.

Certificate review fields

Field Buyer check Typical reason
Tool ID Serial or unique ID matches item Prevents certificate mix-ups
Results Values shown at stated points Supports an independent acceptance decision
Direction and units Match the order and application Avoids accepting an irrelevant test
Uncertainty and reference Reported or traceable as specified Shows measurement quality and provenance
Adjustable torque wrench with a graduated setting scale
A torque wrench shown as a product reference. Its appearance and scale do not establish current accuracy, calibration results or laboratory accreditation. Photo: Sunnyhappy123. License: CC BY-SA 4.0. Source page. Image processing: Resized proportionally; full image retained with white padding where needed.

3. Does a calibration certificate mean a wrench passes?

Not always. Calibration reports results and uncertainty; your stated tolerance and decision rule determine acceptance. A supplier may report measurements without deciding whether they fit your application. Manufacturer guidance notes this distinction in practice; for example, STAHLWILLE’s calibration FAQ explains why its certificate reports maximum measurement error and uncertainty rather than a universal pass label.

Before ordering, name the tolerance source, decision owner, uncertainty rule, and report details. Avoid vague “accuracy certificates” without tested points or a tolerance basis.

  • Define the allowed error for each required point or range.
  • Decide whether results must be reported before and after adjustment.
  • State how uncertainty will be treated near a tolerance boundary.
  • Document who releases a tool when a result sits close to the limit.

The number on the certificate needs a rule beside it. A result near a limit may need review under your quality procedure. Do not borrow another model’s tolerance. See the click versus digital torque wrench buyer guide for tool-format context. Put the acceptance rule in your RFQ.

Acceptance decision inputs

Input Specify before purchase Why it matters
Tolerance source Standard, drawing, or internal procedure Establishes the pass boundary
Test points Required values within usable range Makes reports comparable
Uncertainty rule How uncertainty affects acceptance Handles near-limit results consistently
Release authority Named buyer or quality role Prevents ad hoc disposition

4. Which torque range and test points should the RFQ name?

Specify the nominal range and working values used in production. A wide range may not suit targets near its lower end. Confirm the model’s usable range and procedure, then request results at agreed points. “Test full range” alone is too vague.

For mixed stock, define model-specific points, units, and direction. If users work in N·m and lbf·ft, require clear tool labels and certificate units. Match capacity to the fastening task.

  • List each model and nominal range in the purchase schedule.
  • Name the target values that matter for the application.
  • Require the supplier to identify any uncalibrated or excluded part of the scale.
  • Confirm direction-specific results where both directions are required.

Range coverage should follow the job. List high-volume and maintenance targets separately. Reported points do not imply a separate reading at every intervening value. See socket drive sizes when matching drive interfaces. Send target values with your RFQ.

Range specification checklist

RFQ item Example of a clear request Avoid
Nominal range Exact model range and unit “Standard torque wrench”
Test points Named application values “Check the wrench”
Operating direction Clockwise, counterclockwise, or both Leaving direction unstated
Excluded scale area Supplier identifies any limitation Assuming whole scale is covered

5. How should direction and tool configuration appear in the report?

Many click-type wrenches measure in one direction even when the ratchet head reverses. Ask the manufacturer to identify the model’s measuring direction. If your process needs both, require results for both or specify a suitable tool.

Record the tested configuration. Interchangeable heads, adapters, extensions, or offset attachments can change effective length or loading point. Ask whether attachments were included in the test. For crowfoot setups, use your approved calculation method. The crowfoot wrench torque calculation guide covers that setup question.

  • Record model, head type, drive, and any attachment used.
  • State the torque direction required for the task.
  • Ask whether a configuration change requires recalibration or a documented check.
  • Keep separate records when accessories create a distinct measurement setup.

A reversible head can create false confidence. Confirm which directions the mechanism measures. Do not infer coverage from ratchet movement. Have engineering approve setups that change effective length.

Configuration record

Configuration detail Record or confirm Risk if omitted
Measuring direction CW, CCW, or both Unsupported use direction
Head or drive Fixed, interchangeable, or adapter Different loading geometry
Accessories Identify attachments included in test Certificate may not cover work setup
Setup change State review or recalibration rule Untracked change in torque relationship

6. What do traceability and uncertainty tell a buyer?

Traceability links a result through a documented chain to recognized references. It does not guarantee a production outcome. ISO 6789-2 addresses calibration and measurement uncertainty for hand torque tools. Ask what reference supports the result and how uncertainty appears on the certificate. ISO’s published scope is the best starting point for that technical requirement.

If your contract requires an accredited laboratory, check whether its scope covers the quantity, range, method, and tool category. Accreditation alone does not prove that a specific calibration falls within scope. A manufacturer’s service page can illustrate the distinction: GEDORE separates accredited laboratory service from factory calibration, with different documents and conditions.

  • Ask whether the certificate is accredited or traceable factory calibration.
  • Check the laboratory’s current scope when accreditation is contractually required.
  • Confirm uncertainty units and reported coverage information are understandable.
  • Match the calibration range to your actual torque values.

Use the report your quality system calls for. Check method, range, and report content. Keep evidence with your acceptance record and document deviations before release. Request scope evidence when audits require laboratory competence.

Traceability review

Requirement Evidence to request Buyer action
Traceable result Reference chain stated on certificate Link document to tool ID
Accredited calibration Current scope and certificate Check range and method coverage
Measurement uncertainty Value and reporting convention Apply contract decision rule
Factory calibration Procedure and results supplied Compare with purchase requirements

7. How should buyers set recalibration intervals?

No single interval fits every wrench or quality system. Start with manufacturer instructions and customer requirements, then review use frequency, load, drops, overloads, environment, storage, handling, and process consequence. A fixed “12 months” or “5,000 cycles” statement should not replace the model-specific instructions and risk review. For example, some manufacturer service references present those figures as recommendations; they are not a universal promise for every tool or process.

Use interim checks when risk warrants closer monitoring. Define operator, points, equipment, and failure response. Quarantine failed tools and review prior work when your procedure requires it.

  • Start with applicable manufacturer instructions and contract requirements.
  • Shorten intervals after impacts, overloads, abnormal results, or demanding service.
  • Extend intervals only when documented history and quality approval support it.
  • Record checks, adjustments, repairs, and disposition decisions by tool ID.

Let the records earn any interval change. Review drift and process impact before extending a controlled period. The torque wrench versus breaker bar guide covers why a precision wrench suits controlled tightening. Assign interval review in your procedure.

Interval decision factors

Factor Tends to call for closer review Record to keep
Use frequency and load Frequent or near-limit operation Cycle or usage estimate
Handling and environment Drops, overload, contamination Incident and storage log
Historical drift Results approaching limits Prior certificates and trend
Process consequence Safety or quality-critical joint Risk and customer requirements

8. What should incoming inspection check on a new or serviced wrench?

Match the physical tool, documents, and purchase specification. Check model, range, serial, units, accessories, condition, direction, test points, and required certificate fields. Define sample methods and acceptance rules before shipment.

After adjustment or repair, request post-work results and final status. Decide whether you need as-found readings and return of the same item. Norbar’s certificate process description shows one example.

  • Match the serial ID on tool, certificate, carton, and receiving record.
  • Review test results against your written tolerance and uncertainty rule.
  • Quarantine missing, mismatched, damaged, or out-of-spec tools.
  • Record approval, rejection, rework, or supplier corrective action.

Make acceptance repeatable. Approve a new model’s report format before mass shipment. Sampling does not create a certificate for every wrench. Keep the report and receiving decision in the tool’s maintenance record. The industrial maintenance tool guide covers related instrument records and receiving controls.

Receiving decision

Condition Suggested disposition Record
Identity and report match Release under approved procedure Receiving approval
Missing or mismatched data Hold and request correction Supplier query and resolution
Out-of-spec or damaged Quarantine and assess impact Nonconformance record
Sample check fails Follow predefined lot rule Sample result and lot decision

9. What calibration documents belong in a supplier RFQ?

A useful RFQ names tool type, range, units, direction, quantity, market, procedure, test points, certificate, traceability or accreditation requirement, and acceptance rule. State whether calibration applies per unit, per sample, or as a separate service.

For private-label programs, state how certificates map to product IDs and which serial or lot data must appear. Ask suppliers to flag exclusions. Verify any claimed laboratory scope directly.

  • Attach a model schedule with range, direction, units, and quantity.
  • List required report fields and certificate type.
  • State whether adjustment, repair, retest, or replacement requires separate approval.
  • Define document delivery format and link between each report and tool ID.

A precise RFQ cuts ambiguity before a receiving dispute. Request a sample certificate and review it against your rule. See the torque wrench sourcing guide for broader product questions. Approve one scope before a volume order.

RFQ document matrix

RFQ field Buyer requirement
Product identity Type, model, range, unit, quantity, unique ID method
Test scope Direction, points, applicable procedure, configuration
Evidence Certificate type, results, uncertainty, reference traceability
Commercial scope Per-unit or sample basis; adjustment, repair, retest terms

10. What should a buyer send when requesting a quotation?

Name product type, torque range, direction, quantity, destination market, and report requirement. Add any customer standard, tolerance, target values, certificate type, or labeling needs. Flag undecided items so suppliers can separate product and document scope.

  • Product type and model or target specification
  • Torque range, units, and operating direction
  • Quantity and destination market
  • Required report, traceability, accreditation, and acceptance criteria

Give procurement and quality one shared request. Compare quotations on matching scope and resolve open requirements before purchase. Send details through the Kolarwin contact form, including product, range, direction, quantity, market, and required report. Confirm service capabilities in writing.

Five buyer FAQs

Q1: Does calibration adjust a torque wrench?
No. Calibration records measured performance. Adjustment changes the tool and should be followed by a new result.

Q2: Does every torque wrench need an accredited calibration certificate?
Only when your contract, quality system, or customer requirement calls for one. Check the lab’s scope for the required range and method.

Q3: How often should a torque wrench be recalibrated?
Use manufacturer instructions and your risk-based quality procedure. Consider usage, handling, environment, historical results, and process consequence.

Q4: Should certificates show as-found and as-left results?
Request both when you need to document incoming condition and post-adjustment performance. Specify this before service begins.

Q5: What belongs in a torque wrench calibration RFQ?
Include tool type, range, units, direction, quantity, market, required report, acceptance rule, and any traceability or accreditation requirement.

Looking for a reliable mechanic tools manufacturer in China?

If you are sourcing hand tools, socket tools, automotive repair tools, mechanic tool sets or OEM private label tools, contact KOLARWIN Tools for factory-direct quotation, customization support and product consultation.

For a distributor or quality buyer, a torque wrench certificate can look complete while leaving key questions unanswered: which range was tested, in which direction, and with what uncertainty? This checklist shows how to specify calibration evidence, compare supplier documents, and set incoming acceptance rules. ISO 6789-2 covers calibration and measurement uncertainty for hand torque tools; buyers can use its scope as a starting point, then match requirements to their process and market.

1. What should a buyer mean by torque wrench calibration?

Calibration compares a tool’s output with a reference under stated conditions. It records the relationship between indicated and measured torque, but does not adjust the wrench or predict future accuracy. ISO 6789-2:2017 covers calibration and measurement uncertainty; Part 1 addresses design and quality conformance. Check your market’s required edition. ISO’s standard page describes Part 2’s scope.

Separate these actions in purchase orders and quality records:

Here is the purchasing distinction: a calibration certificate reports evidence; your quality plan decides whether that evidence is acceptable for a specific process. A certificate can still fail your requirement if range, direction, or uncertainty misses the job. For product-type and mechanism context, see the existing professional torque wrench guide. Ask suppliers to name each service step rather than using “calibrated” as a catch-all.

Buyer record distinction

Record or service What it tells you What it does not prove by itself
Calibration result Relationship to a reference under stated conditions Future performance or automatic acceptance
Verification check Whether a defined check met your rule Full calibration across the required range
Adjustment or repair Work performed on the tool Acceptable performance until a post-work result is recorded

2. What makes a calibration certificate useful?

A useful report identifies the tool and work performed. Ask for manufacturer, model, serial or unique ID, date, procedure, range, units, direction, results, reference equipment, and uncertainty. Request as-found results before adjustment and as-left results afterward when your quality system requires them. Norbar describes this distinction in its calibration service documentation, where its certificates can show both sets of readings.

Check the report against the purchase specification before accepting a batch. A certificate stating only “pass” or “within tolerance” may hide the values needed for your own decision. A certificate without serial identification can also be difficult to connect to a particular wrench after goods enter stock.

A clean document trail saves a second inspection. Link each certificate to the tool ID, lot, receiving record, and service history. Assess factory certificates against your written requirement. Put required fields in the RFQ.

Certificate review fields

Field Buyer check Typical reason
Tool ID Serial or unique ID matches item Prevents certificate mix-ups
Results Values shown at stated points Supports an independent acceptance decision
Direction and units Match the order and application Avoids accepting an irrelevant test
Uncertainty and reference Reported or traceable as specified Shows measurement quality and provenance
Adjustable torque wrench with a graduated setting scale
A torque wrench shown as a product reference. Its appearance and scale do not establish current accuracy, calibration results or laboratory accreditation. Photo: Sunnyhappy123. License: CC BY-SA 4.0. Source page. Image processing: Resized proportionally; full image retained with white padding where needed.

3. Does a calibration certificate mean a wrench passes?

Not always. Calibration reports results and uncertainty; your stated tolerance and decision rule determine acceptance. A supplier may report measurements without deciding whether they fit your application. Manufacturer guidance notes this distinction in practice; for example, STAHLWILLE’s calibration FAQ explains why its certificate reports maximum measurement error and uncertainty rather than a universal pass label.

Before ordering, name the tolerance source, decision owner, uncertainty rule, and report details. Avoid vague “accuracy certificates” without tested points or a tolerance basis.

The number on the certificate needs a rule beside it. A result near a limit may need review under your quality procedure. Do not borrow another model’s tolerance. See the click versus digital torque wrench buyer guide for tool-format context. Put the acceptance rule in your RFQ.

Acceptance decision inputs

Input Specify before purchase Why it matters
Tolerance source Standard, drawing, or internal procedure Establishes the pass boundary
Test points Required values within usable range Makes reports comparable
Uncertainty rule How uncertainty affects acceptance Handles near-limit results consistently
Release authority Named buyer or quality role Prevents ad hoc disposition

4. Which torque range and test points should the RFQ name?

Specify the nominal range and working values used in production. A wide range may not suit targets near its lower end. Confirm the model’s usable range and procedure, then request results at agreed points. “Test full range” alone is too vague.

For mixed stock, define model-specific points, units, and direction. If users work in N·m and lbf·ft, require clear tool labels and certificate units. Match capacity to the fastening task.

Range coverage should follow the job. List high-volume and maintenance targets separately. Reported points do not imply a separate reading at every intervening value. See socket drive sizes when matching drive interfaces. Send target values with your RFQ.

Range specification checklist

RFQ item Example of a clear request Avoid
Nominal range Exact model range and unit “Standard torque wrench”
Test points Named application values “Check the wrench”
Operating direction Clockwise, counterclockwise, or both Leaving direction unstated
Excluded scale area Supplier identifies any limitation Assuming whole scale is covered

5. How should direction and tool configuration appear in the report?

Many click-type wrenches measure in one direction even when the ratchet head reverses. Ask the manufacturer to identify the model’s measuring direction. If your process needs both, require results for both or specify a suitable tool.

Record the tested configuration. Interchangeable heads, adapters, extensions, or offset attachments can change effective length or loading point. Ask whether attachments were included in the test. For crowfoot setups, use your approved calculation method. The crowfoot wrench torque calculation guide covers that setup question.

A reversible head can create false confidence. Confirm which directions the mechanism measures. Do not infer coverage from ratchet movement. Have engineering approve setups that change effective length.

Configuration record

Configuration detail Record or confirm Risk if omitted
Measuring direction CW, CCW, or both Unsupported use direction
Head or drive Fixed, interchangeable, or adapter Different loading geometry
Accessories Identify attachments included in test Certificate may not cover work setup
Setup change State review or recalibration rule Untracked change in torque relationship

6. What do traceability and uncertainty tell a buyer?

Traceability links a result through a documented chain to recognized references. It does not guarantee a production outcome. ISO 6789-2 addresses calibration and measurement uncertainty for hand torque tools. Ask what reference supports the result and how uncertainty appears on the certificate. ISO’s published scope is the best starting point for that technical requirement.

If your contract requires an accredited laboratory, check whether its scope covers the quantity, range, method, and tool category. Accreditation alone does not prove that a specific calibration falls within scope. A manufacturer’s service page can illustrate the distinction: GEDORE separates accredited laboratory service from factory calibration, with different documents and conditions.

Use the report your quality system calls for. Check method, range, and report content. Keep evidence with your acceptance record and document deviations before release. Request scope evidence when audits require laboratory competence.

Traceability review

Requirement Evidence to request Buyer action
Traceable result Reference chain stated on certificate Link document to tool ID
Accredited calibration Current scope and certificate Check range and method coverage
Measurement uncertainty Value and reporting convention Apply contract decision rule
Factory calibration Procedure and results supplied Compare with purchase requirements

7. How should buyers set recalibration intervals?

No single interval fits every wrench or quality system. Start with manufacturer instructions and customer requirements, then review use frequency, load, drops, overloads, environment, storage, handling, and process consequence. A fixed “12 months” or “5,000 cycles” statement should not replace the model-specific instructions and risk review. For example, some manufacturer service references present those figures as recommendations; they are not a universal promise for every tool or process.

Use interim checks when risk warrants closer monitoring. Define operator, points, equipment, and failure response. Quarantine failed tools and review prior work when your procedure requires it.

Let the records earn any interval change. Review drift and process impact before extending a controlled period. The torque wrench versus breaker bar guide covers why a precision wrench suits controlled tightening. Assign interval review in your procedure.

Interval decision factors

Factor Tends to call for closer review Record to keep
Use frequency and load Frequent or near-limit operation Cycle or usage estimate
Handling and environment Drops, overload, contamination Incident and storage log
Historical drift Results approaching limits Prior certificates and trend
Process consequence Safety or quality-critical joint Risk and customer requirements

8. What should incoming inspection check on a new or serviced wrench?

Match the physical tool, documents, and purchase specification. Check model, range, serial, units, accessories, condition, direction, test points, and required certificate fields. Define sample methods and acceptance rules before shipment.

After adjustment or repair, request post-work results and final status. Decide whether you need as-found readings and return of the same item. Norbar’s certificate process description shows one example.

Make acceptance repeatable. Approve a new model’s report format before mass shipment. Sampling does not create a certificate for every wrench. Keep the report and receiving decision in the tool’s maintenance record. The industrial maintenance tool guide covers related instrument records and receiving controls.

Receiving decision

Condition Suggested disposition Record
Identity and report match Release under approved procedure Receiving approval
Missing or mismatched data Hold and request correction Supplier query and resolution
Out-of-spec or damaged Quarantine and assess impact Nonconformance record
Sample check fails Follow predefined lot rule Sample result and lot decision

9. What calibration documents belong in a supplier RFQ?

A useful RFQ names tool type, range, units, direction, quantity, market, procedure, test points, certificate, traceability or accreditation requirement, and acceptance rule. State whether calibration applies per unit, per sample, or as a separate service.

For private-label programs, state how certificates map to product IDs and which serial or lot data must appear. Ask suppliers to flag exclusions. Verify any claimed laboratory scope directly.

A precise RFQ cuts ambiguity before a receiving dispute. Request a sample certificate and review it against your rule. See the torque wrench sourcing guide for broader product questions. Approve one scope before a volume order.

RFQ document matrix

RFQ field Buyer requirement
Product identity Type, model, range, unit, quantity, unique ID method
Test scope Direction, points, applicable procedure, configuration
Evidence Certificate type, results, uncertainty, reference traceability
Commercial scope Per-unit or sample basis; adjustment, repair, retest terms

10. What should a buyer send when requesting a quotation?

Name product type, torque range, direction, quantity, destination market, and report requirement. Add any customer standard, tolerance, target values, certificate type, or labeling needs. Flag undecided items so suppliers can separate product and document scope.

Give procurement and quality one shared request. Compare quotations on matching scope and resolve open requirements before purchase. Send details through the Kolarwin contact form, including product, range, direction, quantity, market, and required report. Confirm service capabilities in writing.

Five buyer FAQs

Q1: Does calibration adjust a torque wrench?
No. Calibration records measured performance. Adjustment changes the tool and should be followed by a new result.

Q2: Does every torque wrench need an accredited calibration certificate?
Only when your contract, quality system, or customer requirement calls for one. Check the lab’s scope for the required range and method.

Q3: How often should a torque wrench be recalibrated?
Use manufacturer instructions and your risk-based quality procedure. Consider usage, handling, environment, historical results, and process consequence.

Q4: Should certificates show as-found and as-left results?
Request both when you need to document incoming condition and post-adjustment performance. Specify this before service begins.

Q5: What belongs in a torque wrench calibration RFQ?
Include tool type, range, units, direction, quantity, market, required report, acceptance rule, and any traceability or accreditation requirement.

Why Partner with Kolarwin Tools?

Factory-Direct Pricing Skip the middleman — access competitive wholesale prices and protect your margins
Private Label & OEM Ready Your brand, our expertise — full customization from logo to packaging
Fast Global Shipping Reliable delivery to 60+ countries with full export documentation support
Low MOQ, High Flexibility Start small, scale fast — flexible order quantities to fit your business
Dedicated B2B Support One-on-one account management from quote to delivery, every time

Get Your Free Quote in 24 Hours

Tell us your sourcing needs — we'll respond with a tailored quote, product specs, and the best pricing for your market. No commitment required.

Chat on WhatsApp Email Us Directly